The equipment adopts a post-helium detection method and is equipped with a material transport system featuring a high degree of automation and fast cycle times; each station performs automatic leak detection alternately; the structure adopts a tower type to save floor space. It is equipped with comprehensive protective devices to ensure the safety of operators.
Helium recovery rate: | ≥95% |
Inflation pressure: | 500KPa |
Detection leak rate: | 5.0X10-7Pa·m³/s |
Production cycle: | 120S/chamber |
Chamber door opening method: | Straight pull door |
Vacuum chamber inner cavity dimensions: | Customized according to the shape and size of the workpiece to be tested |