This equipment is suitable for leak detection of power battery lower housings. It can determine whether a product has a leak and pinpoint the exact leak location. The system features a highly automated operating process, enabling fast and efficient batch testing and significantly improving production efficiency. It is equipped with comprehensive protective devices to ensure the safety of operators.
Leak detection method: | Accumulation method at atmospheric pressure & sniffer method, helium detection; |
Inflation pressure: | +3KPa |
Gross leak detection: | Negative pressure detection (-3KPa), (pressure adjustable) |
Micro leak detection |
Alarm leak rate: | Air leak rate 5×10-4Pa·m3/s |
At 6% helium concentration, helium leak rate 3×10-5Pa·m3/s |
Control method: | PLC control, touch screen operation |
Vacuum chamber inner cavity dimensions: | Customized according to the shape and size of the workpiece to be tested |