ULVAC VDN602 and ULVAC VSN2401 adopt a forced oil supply system that ensures stable operation even at high intake pressures. With the use of an oil mist filter, oil recovery device, and heat-resistant seals, continuous operation is possible across the full pressure range below atmospheric pressure. To facilitate daily maintenance, oil level confirmation, oil replenishment, and oil replacement are all performed from the same operating direction.
ULVAC Oil Rotary Vacuum Pump |
Model | VDN602 | VASN2401 |
50 Hz | 60 Hz | 50 Hz | 60 Hz |
Pumping speed | 60 m3/h | 72 m3/h | 240 m3/h | 288 m3/h |
Motor (poles) | 2.2 (4P) | 7.5 (4P) |
Required oil quantity (upper limit – lower limit) | 2.5~4.0 L | 8.0-10.5 L |
Ultimate pressure (gas ballast fully open) | 2.0 Pa | 67 Pa |
ULVAC NB B pumps use a motor one capacity grade larger than the standard motor, enabling operation at high intake pressures without lubricating oil in the pumping chamber, and providing stable exhaust performance for gases such as water vapor and solvents. Capable of operating at high intake pressures.
ULVAC Roots Pump |
Model | NB300B | NB600B | NB1200B | NB2400B |
50 Hz | 60 Hz | 50 Hz | 60 Hz | 50 Hz | 60 Hz | 50 Hz | 60 Hz |
Pumping speed | 280 m3/h | 330 m3/h | 500 m3/h | 600 m3/h | 1000 m3/h | 1200 m3/h | 2000 m3/h | 2400 m3/h |
Maximum intake pressure | 1.2×103 Pa | 9.2×102 Pa | 1.3×103 Pa | 1.1×103 Pa | 1.3×103 Pa | 1.1×103 Pa | 8.0×102 Pa | 6.7×102 Pa |
Maximum allowable pressure difference (discharge pressure - intake pressure) | 4.0×103 Pa | 3.3×103 Pa | 7.3×103 Pa | 6.0×103 Pa | 7.3×103 Pa | 6.0×103 Pa | 5.6×103 Pa | 4.7×103 Pa |
Motor | 0.75 KW | 2.2 KW | 3.7 KW | 7.5 KW |