l Intelligent control system: PLC or industrial computer control, providing a stable and convenient operation interface.
l Fast detection: Automated detection process with high detection speed, capable of efficiently meeting product leak detection requirements.
l Modular design: Customizable modular design according to user needs, with flexible configuration of functional modules such as helium filling, vacuum pumping, and recovery systems to adapt to different product types and detection standards.
l Environmentally friendly and energy-saving: Equipped with an efficient helium recovery system to reduce helium loss and lower operating costs, while meeting environmental protection requirements.
Helium recovery rate: | ≥95% |
Inflation pressure: | 0.01~5.0MPa |
Detection leak rate: | 5g/year |
Production cycle: | 60 S/piece |
Chamber door opening method: | Chamber top-lifting type |
Vacuum chamber inner cavity dimensions: | Customized according to the shape and size of the workpiece to be tested |